iio: accel: adxl380: Add support for 1 kHz sampling frequency
In sensor variants (such as ADXL380 and ADXL382) that support low-power mode, the SAR signal path allows sampling acceleration data at lower rates; more specifically, when the sensor operates in VLP mode, the sampling frequency is 1 kHz. To add support for the 1kHz sampling frequency value, modify the operating mode selection logic to take into account the sampling frequency, and configure the decimation filters only when applicable (i.e. when using a sampling frequency that relies on the DSM signal path); in addition, constrain the available sampling frequency values based on whether the sensor is operating in low-power mode. Signed-off-by: Francesco Lavra <flavra@baylibre.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>